3+DAYS
Smart Storage
Thermostat
Turbo mode
Night mode
LED light
Ultra light
Vitrifrigo Digital Thermostat User Guide
TURNING ON AND OFF
SETTING THE TEMPERATURE
P_SET ( P2 SET) : temperature set button: adjusts the temperature and sets 5 temperature settings (from LD1/LD5)
|
SET TL43 (WITHOUT TURBO AND NIGHT MODE) |
|
|||
|
|
|
|||
|
TEMP. |
|
|
RPM |
|
XOOOO |
+10 |
|
|
2500 |
LED1 |
OXOOO |
+7 |
|
|
2500 |
LED2 |
OOXOO |
+5 |
|
|
2500 |
LED3 |
OOOXO |
+2 |
|
|
2500 |
LED4 |
OOOOX |
-10 |
|
|
3500 |
LED5 |
NIGHT MODE
FUNTION
Activates the related set programs (only active on LED SET 1/2/3/4 see table below). The set lasts for 6 hours then it reverts back to previous/original set.
|
SET NIGHT MODE |
|
|||
|
TEMP. |
|
|
RPM |
|
XOOOO |
+10 |
|
|
2000 |
LED1 |
OXOOO |
+7 |
|
|
2000 |
LED2 |
OOXOO |
+5 |
|
|
2000 |
LED3 |
OOOXO |
+2 |
|
|
2000 |
LED4 |
OOOOX |
-10 |
OFF |
LED5 |
TURBO MODE
FUNCTION
activates the related set programs (active on all LED SET 1/2/3/4/5). This setting stays on until the set temperature is reached, then it switches back to previous setting.
|
SET TURBO MODE |
|
||
|
TEMP. |
|
RPM |
|
XOOOO |
+10 |
|
3500 |
LED1 |
OXOOO |
+7 |
|
|
LED2 |
OOXOO |
+5 |
|
|
LED3 |
OOOXO |
+2 |
|
|
LED4 |
OOOOX |
-10 |
|
3500 |
LED5 |
Flashes |
Error type |
|
5 |
Thermal cut-out of electronic unit
|
If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot |
4 |
Minimum motor speed error
|
If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed 1,850 rpm |
3 |
Motor start error |
The rotor is blocked or the differential pressure in the refrigeration system is too high (>5 bar) |
2 |
Fan over-current cut-out |
The fan loads the electronic unit with more than 1A peak |
1 |
Battery protection cut-out |
The voltage is outside the cut-out setting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|